EL1000N
Main characteristics
- Electrolysis type: PEM (Proton exchange membrane, caustic free)
- Number of cell stacks: 5
Hydrogen gas production
- Max. nominal hydrogen flow: 89 kg/h
- Hydrogen flow range: 10 – 100%
- Operating pressure: 15 – 40 barg (217-580 psig)
- Hydrogen purity (before gas purification): > 99.9%; < 25 ppm O2; H2O saturated
- Hydrogen purity (after gas purification): As per ISO 14687
Electrical requirements
- Voltage: 6.6-24 kV for rectifiers and 3 x 400 VAC ± 10% (3Ph+N) / 3 x 480 VAC ± 10% (3Ph+N) for BoP
- Frequency: 50 Hz ± 5% / 60 Hz ± 3%
- Total installed power: 6,700 kW
- Stack Consumption (*): ≤ 54.0 kWh/kg H2
- AC Power Consumption (BoP + stack) (*): ≤ 57.7 kWh/kg H2 (5,135.3 kW Nominal Power @ BoL, 100% load)
Feed Water - Demi Water (optional Water Treatment Plant is not included)
- Consumption: < 1 L/Nm3 H2
- Conductivity: > 10 MΩcm (< 0.1 uS/cm); TOC < 30 ppb
- Pressure: 8-10 barg (116-145 psig)
- Temperature: +5 ºC to + 35 ºC (+41 ºF to + 95 ºF)
Control system
- PLC: Fully automated and unattended with 15″ color touch screen
- Communication: Modbus TCP/IP or Profinet (RJ45 port)
Environmental conditions
- Ambient temperature range: +5 ºC to + 45 ºC (+41 ºF to +113 ºF)
- Humidity: 0 to +95% (non-condensing)
- Air ventilation: Available from a non-hazardous area
- Installation area: Indoor/Outdoor
Dimensions and weight
- Dimensions (LxWxH): 2 x [40ft container (12.0m x 2.4m x 2.9m) (39.4ft x 7.9ft x 9.5ft)] + 2 x [20ft container (6.0m x 2.4m x 2.9m) (19.7ft x 7.9ft x 9.5ft)]
- Approx. weight: 58,000 kg (127,868 lb)
Standards & regulations
Compliance*: CE, ISO 22734-1 / NFPA 2-2020 & NFPA 70
Other characteristics
- Duty cycle: 100% (24/7)
- Start-up time (from stand-by): < 30 sec
- Cold start time: < 20 min
- Nitrogen System: For each purge, consumption is <0.2 kg at >1 barg (to be supplied by the customer).
- Instrumentation air System: Consumption 7 Nm3/h at 10 barg (to be supplied by the customer).
Always included
All our products do always incorporate:
- Hydrogen cooling system
- Emergency shutdown system
- Overpressure relief system
- Redundancy on critical safety parameters
- Uninterruptible Power Supply (UPS)
- Heat management (no cooling water is needed)
- Virtual Private Network (VPN) connection
Additional Options
All our products can include:
- Oxygen processing system
- Hydrogen purification system (SAE J2719 September 2011)
- Water treatment system
- Extreme environmental conditions package (low and high temp)
Hydrogen Mass Flow Measure & Purity Measure (H2O & O2 Sensors)